The multi-channel glue gun is an important component of the automatic glue coating system, and in the production of automotive glue coating, it is inevitable to encounter some equipment problems that affect the progress. Today we will take stock of some common problems and their corresponding solutions.
Fault phenomenon: nozzle glue overflow
Reason 1: Damaged valve needle and seat components
Solution: Check and replace valve needle and seat components
Reason 2: Damaged valve seat seal
Solution: Check and replace valve seat seal
Reason 3: Dirty or foreign objects on the sealing surface of the valve needle and valve seat.
Solution: Clean the dirty or foreign objects on the sealing surface of the valve needle and valve seat
Reason 4: Failure or damage of spring number 106
Solution: Check and replace spring number 106
Fault phenomenon: glue overflow at the connection of the gun head
Reason 1: Seal damage
Solution: Check and replace the corresponding seal
Reason 2: Excessive work pressure
Solution: Do not exceed the working pressure of the equipment
Fault phenomenon: Abnormal spray amplitude, spray interruption, spray branching, uneven thickness
Reason 1: Damaged nozzle
Solution: Check and replace the nozzle
Reason 2: Foreign objects or dry glue in the nozzle
Solution: Clean the nozzle of dirt or foreign objects
Reason 3: The large temperature changes in the glue supply system lead to significant changes in the viscosity of the glue.
Solution: Improve or adjust the glue temperature control system to stabilize its temperature and viscosity
Reason 4: System pressure changes
Solution: Improve or adjust the system pressure control to make it stable
Fault phenomenon: Continuous overflow of glue from the observation hole of the gun head
Reason: Damaged valve needle seal
Solution: Check and replace valve needle seal component with serial number 1307
Fault phenomenon: Continuous overflow and glue string in the stator observation hole
Reason 1: Damage to the sealing component of the stator fluid block
Solution: Check and replace the seal with serial number 1102
Reason 2: Fluid shaft wear
Solution: Check and replace serial number 1202 fluid shaft
Fault phenomenon: Airway leakage, unable to shoot, slow shooting
Reason 1: Damaged seal of stator airway block
Solution: Check and replace seal with serial number 302
Reason 2: Spindle damage
Solution: Check and replace spindle with serial number 208
Reason 3: Damaged piston or piston rod seal
Solution: Check and replace seal with serial number 203, seal with serial number 206207
Fault phenomenon: Rotation stuck, abnormal torque
Reason 1: Bearing damage Solution: Check and replace bearings numbered 103,6
Reason 2: Damaged main shaft and fluid shaft seals Solution: Check and replace the sealing ring with serial number 3021102
Reason 3: Wear and damage to the spindle and fluid shaft Solution: Check and replace the spindle with serial number 208 and the fluid shaft with serial number 1202