The automatic glue gun GA4000 is often used in the automatic glue coating system of automobile manufacturing. In the daily production and manufacturing process, the glue gun can not work normally for different reasons. Today, we will inventory some common problems and related solutions of the automatic glue gun GA4000.
Rubber nozzle continuous overflow glue
Reason 1 : Over the rated operating pressure Solution : Do not exceed the rated operating pressure
Cause 2 : valve seat, valve core and seal damage solution : replace the corresponding parts
Throat overflow glue
Reason 1 : Over the rated operating pressure Solution : Do not exceed the rated operating pressure
Cause 2 : Laryngeal lubrication components seal damage Solution : Replace the corresponding parts
Gun off delay
Reason 1 : Shut off the gun for insufficient gas supply Solution : check the solenoid valve supply pressure and solenoid valve specifications are satisfied with the use
Reason 2 : Solenoid valve installation distance is too far solution : minimize the installation distance
Cause 3 : solution to the leakage of the gun cylinder : check and replace the relevant sealing ring
Heating failure or temperature control out of control
Reason 1 : PID parameters of temperature control system are not correct Solution : Check and correct PID parameters of temperature control
Cause 2 : electric heating rod damage ; temperature sensor damage solution : replace the heating gun seat module or replace the corresponding electrical components and check the test